Analysis of common faults of air compressors
First, the main reason for the air compressor to burn tiles?
(1) The amount of oil in the oil pan (or crankcase) is insufficient, or the oil circuit is not smooth, resulting in poor lubrication;
(2) The oil pressure is too low, the normal oil pressure should be 0.15 0. 3MPa, when the oil pressure is lower than 0.08MPa, it should be
Stop immediately for inspection.
(3) The mating contact surface between the bearing bush and the bell neck does not meet the requirements, usually the contact area is not less than 75%, and the distribution of contact points
If the assembly gap between the uranium bush and the journal is too large or too small, the oil cannot form a fixed oil film during lubrication, and the
Poor lubrication.
(4) The ovality of the crankshaft journal exceeds the requirements, so that the oil cannot form a certain oil film during the lubrication process, resulting in poor lubrication.
(5) The back of the big end of the connecting rod is worn, causing the back of the bearing bush and the big end of the connecting rod to be unable to fit closely, causing the bearing bush of the connecting rod to burn.
(6) The quality of the bearing bush alloy is not good, and the alloy and the bottom tile cannot be completely and tightly fitted together.
(7) The center of each main bush is inconsistent, causing the crankshaft to run in the main bush, and some places are large and thin, resulting in dry friction and strict
When it is heavy, it will cause tile burning.
Second, the air compressor is not pumping?
Fault phenomenon: The air compressor discharges without pressure air.
cause of issue